PROCOM A/S

PRO-PHY450-4

4-Channel Hybrid Combiner for 450 MHz Transmitters

DESCRIPTION

  • Combining four transmitters or receivers on the same antenna.
  • Better utilisation of good antenna position.
  • Four antennas on the same transmitter or receiver.
  • The only combining option with very small TX-TX frequency spacing.
  • 60 W load supplied (other loads or no load as option).

ORDERING DESIGNATIONS

TYPE PRODUCT NO. FREQ. RANGE
PRO-PHY450-4-TETRA 210001667 380 - 400 MHz
PRO-PHY450-4-1 210000880 400 - 405 MHz
PRO-PHY450-4-2 210000712 404 - 409 MHz
PRO-PHY450-4-3 210000698 408 - 413 MHz
PRO-PHY450-4-4 210000735 412 - 417 MHz
PRO-PHY450-4-5 210000577 416 - 421 MHz
PRO-PHY450-4-6 210000582 420 - 425 MHz
PRO-PHY450-4-7 210000644 424 - 429 MHz
PRO-PHY450-4-8 210000586 428 - 433 MHz
PRO-PHY450-4-9 210000809 432 - 437 MHz
PRO-PHY450-4-10 210000715 436 - 441 MHz
PRO-PHY450-4-11 210000834 440 - 445 MHz
PRO-PHY450-4-12 210000833 444 - 449 MHz
PRO-PHY450-4-13 210000713 448 - 453 MHz
PRO-PHY450-4-14 210000581 452 - 457 MHz
PRO-PHY450-4-15 210000665 456 - 461 MHz
PRO-PHY450-4-16 210000610 458 - 463 MHz
PRO-PHY450-4-17 210000584 462 - 467 MHz
PRO-PHY450-4-18 210000643 466 - 471 MHz
PRO-PHY450-4-19 210000891 470 - 475 MHz

SPECIFICATIONS

ELECTRICAL
FILTER TYPE Hybrid Junction
FREQUENCY 380 - 475 MHz (see table)
MAX. INPUT POWER 65 W per channel
(max. 150 W with larger load)
INSERTION LOSS < 6.3 dB ± 0.3 dB @ 11 MHz BW
< 6.6 dB ± 0.3 dB @ 22 MHz BW
ISOLATION TX 1-TX 2
(*see note)
> 32 dB @ 11 MHz BW
> 28 dB @ 22 MHz BW
IMPEDANCE Nom. 50 Ω
LOAD 60 W load fitted (other ratings available)
SWR < 1.5 with all other ports terminated
with 50 Ω
MECHANICAL
TEMP. RANGE –30° C → +60° C
CONNECTORS N-female (other types as option)
DIMENSIONS (L x W x H) 420 x 89 (incl. conn.) x 42 mm
WEIGHT Approx. 1330 g (excl. load)

*The isolation between the TX ports is directly dependent on the terminating SWR on the antenna port. With an antenna load SWR = 1.5, the isolation between the two TX ports will be reduced to 20 dB @ 5 MHz bandwidth.
**The SWR of the loads should be < 1.1! Each load should be able to dissipate 3/4 of the input power.
E.g.: With 50 W input, each load should be able to dissipate
50 W x 3/4 = 37 W.

TYPICAL ISOLATION RESPONSE

To top
SpecificationsIn PDF Format
Print this page

PROCOM A/S Smedetoften 12 • DK - 3600 Frederikssund Denmark • Phone: +45 48 27 84 84 • E-mail: info@procom.dk